Home / Refrigeration / Electrical Components, Relays, Capacitors Product Description Contactor Normally Open A30-30-10 220-230V 50Hz A30 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuitNormally Open220-230V 50Hz . AC-1 : 55AAC-3 : 15 Kw -400V TechnicalNumber of Main Contacts NO: 3Number of Main Contacts NC : 0Number of Auxiliary Contacts NO: 1Number of Auxiliary Contacts NC: 0Standards:Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1Rated Operational Voltage:Main Circuit 690 VRated Frequency (f):Supply Circuit 50 60 HzConventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 65 Aacc. to IEC 60947-5-1, q = 40 °C 16 ARated Operational Current AC-1 (Ie):(690 V) 40 °C 55(690 V) 55 °C 55(690 V) 70 °C 39Rated Operational Current AC-3 (Ie):(415 V) 55 °C 32 A(440 V) 55 °C 32 A(500 V) 55 °C 28 A(690 V) 55 °C 21 A(380 / 400 V) 55 °C 32 A(220 / 230 / 240 V) 55 °C 33Rated Operational Power AC-3 (Pe):(415 V) 15 kW(440 V) 18.5 kW(500 V) 18.5 kW(690 V) 18.5 kW(380 / 400 V) 15 kW(220 / 230 / 240 V) 9 kWRated Operational Power AC-6b (Pe):(230 / 240 V) 40 °C, 50 / 60 Hz 13 kvar(230 / 240 V) 55 °C, 50 / 60 Hz 13 kvar(230 / 240 V) 70 °C, 50 / 60 Hz 11 kvar(400 / 415 V) 40 °C, 50 / 60 Hz 22 kvar(400 / 415 V) 70 °C, 50 / 60 Hz 18.5 kvar(400 / 415 V) 55 °C, 50 / 60 Hz 22 kvar(440 V) 40 °C, 50 / 60 Hz 24 kvar(440 V) 55 °C, 50 / 60 Hz 24 kvar(440 V) 70 °C, 50 / 60 Hz 20.5 kvar(500 / 550 V), 40 °C, 50 / 60 Hz 28 kvar(500 / 550 V) 55 °C, 50 / 60 Hz 28 kvar(500 / 550 V) 70 °C, 50 / 60 Hz 23 kvar(690 V) 40 °C, 50 / 60 Hz 38 kvar(690 V) 55 °C, 50 / 60 Hz 38 kvar(690 V) 70 °C, 50 / 60 Hz 32 kvarRated Breaking Capacity AC-3 acc. to IEC 60947-4-1:8 x Ie AC-3Rated Making Capacity AC-3 acc. to IEC 60947-4-1:10 x Ie AC-3Rated Operational Current AC-15 (Ie):(500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(380 / 400 V) 3 AShort-Circuit Protective Devices:Auxiliary Circuit - gG Type Fuses 10 AgG Type Fuses 63 AMaximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 AMaximum Electrical Switching Frequency:(AC-1) 600 cycles per hour(AC-2 / AC-4) 300 cycles per hour(AC-3) 1200 cycles per hourRated Operational Current DC-13 (Ie):(24 V) 6 / 144 A(48 V) 2.8 / 134 A(72 V) 2 / 144 A(125 V) 1.1 / 138 A(250 V) 0.55 / 138 ARated Insulation Voltage (Ui):acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 VRated Impulse Withstand Voltage (Uimp):8 kVMechanical Durability:10 millionMaximum Mechanical Switching Frequency:3600 cycles per hourRated Control Circuit Voltage (Uc):50 Hz 220 ... 230 V60 Hz 230 ... 240 VCoil Consumption:Average Holding Value 50 / 60 Hz 12 3 V·AAverage Pull-in Value 50 Hz 125 V·AAverage Pull-in Value 60 Hz 120 V·AOperate Time:Between Coil De-energization and NO Contact Opening 4 ... 11 msBetween Coil Energization and NO Contact Closing 8 ... 21 msConnecting Capacity Main Circuit:Flexible with Cable End 2.5 ... 10 mm²Rigid Cable 2.5 ... 16 mm²Connecting Capacity Auxiliary Circuit:Flexible with Cable End 0.75 ... 2.5 mm²Rigid Cable 1 ... 4 mm²Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20Connecting Terminals (delivered in open position) Main Poles:M 5 (+,-) pozidriv 2 screw with 2x (5.6x6.5 mm) connectorTerminal Type:Screw TerminalsEnvironmentalAmbient Air Temperature:Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °CClose to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °CClose to Contactor for Storage -60 ... +80 °CClimatic Withstand:acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification IIMaximum Operating Altitude Permissible:3000 mResistance to Shock acc. to IEC 60068-2-27:Closed, Shock Direction: B1 10 K40Open, Shock Direction: B1 5 K40Shock Direction: A 20 K40Shock Direction: B2 15 K40Shock Direction: C1 20 K40Shock Direction: C2 20 K40RoHS Status:Following EU Directive 2011/65/EU Specifications Brand AirTech-UK Product Code A30-30-10 Weight 1kg Customer reviews No reviews left yet Write A Review Sort byMost RecentTop Rated Description Contactor Normally Open A30-30-10 220-230V 50Hz A30 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuitNormally Open220-230V 50Hz . AC-1 : 55AAC-3 : 15 Kw -400V TechnicalNumber of Main Contacts NO: 3Number of Main Contacts NC : 0Number of Auxiliary Contacts NO: 1Number of Auxiliary Contacts NC: 0Standards:Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1Rated Operational Voltage:Main Circuit 690 VRated Frequency (f):Supply Circuit 50 60 HzConventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 65 Aacc. to IEC 60947-5-1, q = 40 °C 16 ARated Operational Current AC-1 (Ie):(690 V) 40 °C 55(690 V) 55 °C 55(690 V) 70 °C 39Rated Operational Current AC-3 (Ie):(415 V) 55 °C 32 A(440 V) 55 °C 32 A(500 V) 55 °C 28 A(690 V) 55 °C 21 A(380 / 400 V) 55 °C 32 A(220 / 230 / 240 V) 55 °C 33Rated Operational Power AC-3 (Pe):(415 V) 15 kW(440 V) 18.5 kW(500 V) 18.5 kW(690 V) 18.5 kW(380 / 400 V) 15 kW(220 / 230 / 240 V) 9 kWRated Operational Power AC-6b (Pe):(230 / 240 V) 40 °C, 50 / 60 Hz 13 kvar(230 / 240 V) 55 °C, 50 / 60 Hz 13 kvar(230 / 240 V) 70 °C, 50 / 60 Hz 11 kvar(400 / 415 V) 40 °C, 50 / 60 Hz 22 kvar(400 / 415 V) 70 °C, 50 / 60 Hz 18.5 kvar(400 / 415 V) 55 °C, 50 / 60 Hz 22 kvar(440 V) 40 °C, 50 / 60 Hz 24 kvar(440 V) 55 °C, 50 / 60 Hz 24 kvar(440 V) 70 °C, 50 / 60 Hz 20.5 kvar(500 / 550 V), 40 °C, 50 / 60 Hz 28 kvar(500 / 550 V) 55 °C, 50 / 60 Hz 28 kvar(500 / 550 V) 70 °C, 50 / 60 Hz 23 kvar(690 V) 40 °C, 50 / 60 Hz 38 kvar(690 V) 55 °C, 50 / 60 Hz 38 kvar(690 V) 70 °C, 50 / 60 Hz 32 kvarRated Breaking Capacity AC-3 acc. to IEC 60947-4-1:8 x Ie AC-3Rated Making Capacity AC-3 acc. to IEC 60947-4-1:10 x Ie AC-3Rated Operational Current AC-15 (Ie):(500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(380 / 400 V) 3 AShort-Circuit Protective Devices:Auxiliary Circuit - gG Type Fuses 10 AgG Type Fuses 63 AMaximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 AMaximum Electrical Switching Frequency:(AC-1) 600 cycles per hour(AC-2 / AC-4) 300 cycles per hour(AC-3) 1200 cycles per hourRated Operational Current DC-13 (Ie):(24 V) 6 / 144 A(48 V) 2.8 / 134 A(72 V) 2 / 144 A(125 V) 1.1 / 138 A(250 V) 0.55 / 138 ARated Insulation Voltage (Ui):acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 VRated Impulse Withstand Voltage (Uimp):8 kVMechanical Durability:10 millionMaximum Mechanical Switching Frequency:3600 cycles per hourRated Control Circuit Voltage (Uc):50 Hz 220 ... 230 V60 Hz 230 ... 240 VCoil Consumption:Average Holding Value 50 / 60 Hz 12 3 V·AAverage Pull-in Value 50 Hz 125 V·AAverage Pull-in Value 60 Hz 120 V·AOperate Time:Between Coil De-energization and NO Contact Opening 4 ... 11 msBetween Coil Energization and NO Contact Closing 8 ... 21 msConnecting Capacity Main Circuit:Flexible with Cable End 2.5 ... 10 mm²Rigid Cable 2.5 ... 16 mm²Connecting Capacity Auxiliary Circuit:Flexible with Cable End 0.75 ... 2.5 mm²Rigid Cable 1 ... 4 mm²Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20Connecting Terminals (delivered in open position) Main Poles:M 5 (+,-) pozidriv 2 screw with 2x (5.6x6.5 mm) connectorTerminal Type:Screw TerminalsEnvironmentalAmbient Air Temperature:Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °CClose to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °CClose to Contactor for Storage -60 ... +80 °CClimatic Withstand:acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification IIMaximum Operating Altitude Permissible:3000 mResistance to Shock acc. to IEC 60068-2-27:Closed, Shock Direction: B1 10 K40Open, Shock Direction: B1 5 K40Shock Direction: A 20 K40Shock Direction: B2 15 K40Shock Direction: C1 20 K40Shock Direction: C2 20 K40RoHS Status:Following EU Directive 2011/65/EU Reviews No reviews left yet Write A Review Sort byMost RecentTop Rated Attributes Brand AirTech-UK Product Code A30-30-10 Weight 1kg Delivery & Returns As per our terms and conditions. Customer Reviews Contactor A30-30-10 A30-30-10 220-230V 50Hz Normally Open Item in Stock Product Code A30-30-10 £30.45 £25.38 (ex. VAT) Login to add this product to your wishlist. You Will Earn 30 points which is the equivalent of £0.30